Safety Usage Requirements and Common Malfunctions of Centrifuges
发布时间:2025-04-15 14:58:09 人气:1012 来源:本站
Safety Usage Requirements of Centrifuges: 1. Select the correct type. 2. Use the centrifuge within the specified range. Do not use a centrifuge for general purposes in explosive, flammable, or corrosive environments. 3. Operate according to the specified operating procedures. Do not apply abnormal braking, overload operation, or operate at excessive speeds. 4. Eliminate malfunctions in a timely manner. Do not operate a centrifuge with faults, and scrap the ineffective centrifuge in a timely manner. 5. Install, use, and maintain the centrifuge in accordance with the requirements in the product instruction manual. Do not modify the components of the centrifuge on your own, and do not increase the rotation speed of the centrifuge by yourself. 6. Formulate corresponding rules and regulations for the installation, use, and maintenance of the centrifuge and strictly implement them to achieve the purpose of safe use. Analysis and Troubleshooting of Common Malfunctions: Motor Overheating**: There are generally the following situations for motor overheating: 1. The starting time of a general three-legged centrifuge is ≤60s. If the starting time is long, it may be due to the wear of the throwing blocks, the light weight, the presence of oil stains on the surface of the friction plate, or quality problems with the motor. Therefore, it is necessary to replace the new throwing blocks or check the motor. 2. The starting current is large. The starting current of a general three-legged centrifuge is about 2.5 times the rated current, and the starting current under load is about 3 times the rated current. If the current exceeds this value, it may be due to quality problems with the motor, whether the power line is correct, whether the motor shaft is bent, whether there is a jamming phenomenon in the clutch, or whether the clutch throwing blocks are overweight. Vibration: 1. Large vibration during no-load operation: The vibration of the centrifuge is mainly caused by the imbalance of the drum mass, the too large gap between the drum supports, and the loosening of the bolts and nuts at the connecting parts. If the centrifuge has been used for a long time and is severely corroded, the possibility of cracks in the drum welds or other parts should be considered. Sometimes, too much accumulated material in the drum causes the drum to be unbalanced, which will also cause vibration. Other reasons, such as a bent main shaft or damaged bearings, may also cause vibration. 2. Large vibration during load operation: In addition to the above reasons, the large vibration during load operation is mainly caused by the unbalanced distribution of materials, resulting in unbalance and vibration. This can be solved by adjusting the feeding method and evenly distributing the materials. Secondly, it may be because the drum has been used for a long time or has been knocked and deformed. During the use process, the thickness of the filter cake layer formed in the drum cannot be evenly distributed, so the machine will vibrate.
相关新闻
- 台式高速冷冻离心机怎么选 实验室离心必备指南 2026-04-02
- 水平转子选型必看 三大优势你知道几个 2026-04-02
- 台式低速冷冻离心机选购指南 实验室样品分离的必备之选 2026-04-01
- 实验室离心机角转子怎么选 牢记这几点选对不踩坑 2026-04-01
- 实验室必备台式高速冷冻离心机怎么选怎么用 2026-03-31
- 实验室离心机怎么选台式高速冷冻离心机的三大核心要点 2026-03-31
- 水平转子怎么选?关注离心力和容量,分离更高效 2026-03-23
- 水平转子怎么选?离心力计算和角转子区别一看就懂 2026-03-23
- 台式高速冷冻离心机怎么选?抓住转速这个关键点 2026-03-22
- 台式低速冷冻离心机怎么选?掌握这几点实验更稳更准 2026-03-22


客服